A SPARC-class design with 18 toroidal field coils, built in Whet. Two solver results, and an audit that is not finished.
Tokamak study
A SPARC-class design with 18 TF coils, and where it fails.
SPARC-class, R0 1.85 m, minor radius 0.57 m. Coil case peak von Mises, element: 929 MPa against a 1000 MPa yield at 4 K, a factor of safety of 1.08. The colour scale is drawn from the nodal average, a different reading, and tops at 1016 MPa. tok-coil-stress, 2026-09-30
Divertor under 10 MW/m2: 771.9 C peak. The thermal stress gives a factor of safety of 0.16, so the design needs an interlayer. tok-tile-temperature, 2026-09-30
What was checked
287 parts placed.
The audit is not finished: 3661 of about 4300 pair checks were run. No overlap or fastener count is claimed.
tok-coil-stress, 2026-09-30
What was computed
Coil case: peak von Mises, element, 929 MPa against a typed yield of 1000 MPa at 4 K, a factor of safety of 1.08. The colour scale is drawn from the nodal average, a different reading, and tops at 1016 MPa.
Divertor module under 10 MW/m2 on the middle tile: 771.9 C peak. The thermal stress gives a factor of safety of 0.16, so the design needs an interlayer.
tok-coil-stress, 2026-09-30
Reference
SPARC as published, Creely et al., J. Plasma Phys. 86 (2020) 865860502: major radius 1.85 m, minor radius 0.57 m, elongation 1.97, triangularity 0.54, 12.2 T on axis, 18 toroidal field coils, double-null divertor. The coil build, vessel, ports, cryostat and supports are sized for this model, not taken from any SPARC drawing.
tok-coil-stress, 2026-09-30
Not done yet
The audit is incomplete: no result is stated for overlaps, contact or fasteners.
The material figures are typed, not cards: 316LN at 4 K, the winding pack, tungsten and CuCrZr. No card on the shelf covers them.
The coil load is one coil under the centring pressure on its inner leg, held as a vault of 18 wedged coils.
The divertor run is five tungsten tiles on a CuCrZr heat sink, 10 MW/m2 on one tile and 1 MW/m2 on four, the back face water cooled. No interlayer is modelled.
A vacuum vessel frequency study is specified; no result is shown.